Error codes

AMT PostPro error codes for PostPro3D, SF50 and SF100

129 error codes and what the screen says. For the checks to make, press Ask Lorin beside the code, or describe the fault to Lorin.

Jump to: PostPro3D · SF50 and SF100

PostPro3D error codes 122 codes

CodeWhat the screen saysTypeHelp
HE0Emergency stop (sr1)NotificationAsk Lorin
HE1Ball valve open timeout (bv1)ErrorAsk Lorin
HE10Ball valve open timeout (bv4)ErrorAsk Lorin
HE11Ball valve close timeout (bv4)ErrorAsk Lorin
HE12Ball valve sensor error (bv4)ErrorAsk Lorin
HE16Ball valve open timeout (bv6)ErrorAsk Lorin
HE17Ball valve close timeout (bv6)ErrorAsk Lorin
HE18Ball valve sensor error (bv6)ErrorAsk Lorin
HE19Ball valve open timeout (bv7)ErrorAsk Lorin
HE2Ball valve close timeout (bv1)ErrorAsk Lorin
HE20Ball valve close timeout (bv7)ErrorAsk Lorin
HE21Ball valve sensor error (bv7)ErrorAsk Lorin
HE22Ac power failure (vm1)ErrorAsk Lorin
HE23Htf pump motor error (ss1)ErrorAsk Lorin
HE24Analog input disconnect (ai10)ErrorAsk Lorin
HE25Analog input disconnect (ai11)ErrorAsk Lorin
HE26Analog input disconnect (ai12)ErrorAsk Lorin
HE27Analog input disconnect (ai13)ErrorAsk Lorin
HE28Analog input disconnect (ai14)ErrorAsk Lorin
HE29Analog input disconnect (ai15)ErrorAsk Lorin
HE3Ball valve sensor error (bv1)ErrorAsk Lorin
HE30Analog input disconnect (ai16)ErrorAsk Lorin
HE31Analog input disconnect (ai17)ErrorAsk Lorin
HE32Analog input disconnect (ai20)ErrorAsk Lorin
HE33Analog input disconnect (ai21)ErrorAsk Lorin
HE34Analog input disconnect (ai22)ErrorAsk Lorin
HE35Analog input disconnect (ai23)ErrorAsk Lorin
HE36Analog input disconnect (ai24)ErrorAsk Lorin
HE37Analog input disconnect (ai25)ErrorAsk Lorin
HE38Analog input disconnect (ai26)ErrorAsk Lorin
HE39Analog input disconnect (ai27)ErrorAsk Lorin
HE4Ball valve open timeout (bv2)ErrorAsk Lorin
HE40Analog input disconnect (ai30)ErrorAsk Lorin
HE41Analog input disconnect (ai31)ErrorAsk Lorin
HE42Analog input disconnect (ai32)ErrorAsk Lorin
HE43Analog input disconnect (ai33)ErrorAsk Lorin
HE44Analog input disconnect (ai34)ErrorAsk Lorin
HE45Analog input disconnect (ai35)ErrorAsk Lorin
HE46Analog input disconnect (ai36)ErrorAsk Lorin
HE47Analog input disconnect (ai37)ErrorAsk Lorin
HE48Cc-link communication error (plc0)ErrorAsk Lorin
HE49Rs485 communication error (plc0)ErrorAsk Lorin
HE5Ball valve close timeout (bv2)ErrorAsk Lorin
HE50Self diagnostics error (plc0)ErrorAsk Lorin
HE51I/o module verify error (plc0)ErrorAsk Lorin
HE52CPU SCAN TIME ABOVE 100ms (PLC0)ErrorAsk Lorin
HE53Vacuum pump vfd alarm (inv1)ErrorAsk Lorin
HE54Cpu error (plc0)ErrorAsk Lorin
HE6Ball valve sensor error (bv2)ErrorAsk Lorin
HE7Ball valve open timeout (bv3)ErrorAsk Lorin
HE8Ball valve close timeout (bv3)ErrorAsk Lorin
HE9Ball valve sensor error (bv3)ErrorAsk Lorin
IE0Ups alarm (ps2)ErrorAsk Lorin
IE1Ups battery discharging (ps2)ErrorAsk Lorin
IE10Chamber temperature difference above 20°c (tc9; tc10)ErrorAsk Lorin
IE11Hot plate temperature above 180°c (tc11)ErrorAsk Lorin
IE12Hot plate temperature above 180°c (tc12)ErrorAsk Lorin
IE13Hot plate temperature difference above 20°c (tc11; tc12)ErrorAsk Lorin
IE14AIR PRESSURE INSIDE CONDENSER ABOVE 1500mBar (PR3)ErrorAsk Lorin
IE15AIR PRESSURE INSIDE FILTER ABOVE 1500mBar (PR4)ErrorAsk Lorin
IE16AIR PRESSURE INSIDE FILTER ABOVE 1500mBar (PR5)ErrorAsk Lorin
IE17AIR FILTER PRESSURE DIFFERENCE ABOVE 250mBar (PR4; PR5)ErrorAsk Lorin
IE18Virgin consumable level below 5% (ls1)NotificationAsk Lorin
IE19Used consumable level above 95% (ls2)NotificationAsk Lorin
IE2Fume extractor error (ext)ErrorAsk Lorin
IE20Lid slide actuator error (sd1)ErrorAsk Lorin
IE21Lid lock actuator error (sd2)ErrorAsk Lorin
IE22Lid slide incorrect position (sd1)ErrorAsk Lorin
IE23Lid lock incorrect position (sd2)ErrorAsk Lorin
IE24Vacuum pump vfd error (inv1)ErrorAsk Lorin
IE25Lid slide open timeout (sd1)ErrorAsk Lorin
IE26Lid slide close timeout (sd1)ErrorAsk Lorin
IE27Lid lock open timeout (sd2)ErrorAsk Lorin
IE28Lid lock close timeout (sd2)ErrorAsk Lorin
IE29CAN’T REACH 200mBar IN PC (STUCHK 1100)ErrorAsk Lorin
IE3Coolant inlet temperature above 25°c (tc1)ErrorAsk Lorin
IE30Can’t hold vacuum (stuchk 1400)ErrorAsk Lorin
IE31Solenoid valve error (stuchk 1450)ErrorAsk Lorin
IE32Pressure sensor error (stuchk 1600)ErrorAsk Lorin
IE33Coolant temperature error (stuchk 1700)ErrorAsk Lorin
IE34Htf temperature error (stuchk 1800)ErrorAsk Lorin
IE35Htf heating timeout (stuchk 2100)ErrorAsk Lorin
IE36Htf cooling timeout (stuchk 2500)ErrorAsk Lorin
IE37Hot plate heating timeout (stuchk 3100)ErrorAsk Lorin
IE38Htf cooling timeout (procinit 600)ErrorAsk Lorin
IE39Hot plate incorrect temperature (procinit 1000)ErrorAsk Lorin
IE4Vacuum pump outlet temperature above 120°c (tc5)ErrorAsk Lorin
IE40Heating timeout (procinit 1200)ErrorAsk Lorin
IE41Can’t reach specified pressure in pc (proc 300)ErrorAsk Lorin
IE42Solenoid valve error (proc 600)ErrorAsk Lorin
IE43Consumable flow meter air bubble detection (fm1)ErrorAsk Lorin
IE44Heating timeout (main 21500)ErrorAsk Lorin
IE45Timeout during preparing for drying cycleErrorAsk Lorin
IE46Carbon filter saturation above 95%NotificationAsk Lorin
IE5Htf temperature above 98°c (tc6)ErrorAsk Lorin
IE6Htf temperature above 98°c (tc7)ErrorAsk Lorin
IE7Htf temperature above 98°c (tc8)ErrorAsk Lorin
IE8Htf temperature above 98°c (tc9)ErrorAsk Lorin
IE9Htf temperature above 98°c (tc10)ErrorAsk Lorin
SE0Recipe parameter errorErrorAsk Lorin
SE1Htf heating timeout (cure 400)ErrorAsk Lorin
SE10Parts drying timeoutErrorAsk Lorin
SE11Consumable injection timeout (proc 800)ErrorAsk Lorin
SE12Out of consumableNotificationAsk Lorin
SE13Bv1 timeoutErrorAsk Lorin
SE14Bv2 timeoutErrorAsk Lorin
SE15Bv3 timeoutErrorAsk Lorin
SE16Bv4 timeoutErrorAsk Lorin
SE18Bv6 timeoutErrorAsk Lorin
SE19Bv7 timeoutErrorAsk Lorin
SE2Hot plate temperature incorrect (proc 100)ErrorAsk Lorin
SE20Timeout during cooling after process runErrorAsk Lorin
SE21Hmi frozen, restarted by plcErrorAsk Lorin
SE22Socket timeout (plc0)ErrorAsk Lorin
SE23Ntp time sync error (plc0)ErrorAsk Lorin
SE3Pc temperature error during processingErrorAsk Lorin
SE4Pc temperature error during dryingErrorAsk Lorin
SE5Pc pressure error during dryingErrorAsk Lorin
SE6Startup check timeoutErrorAsk Lorin
SE7Process initialization timeoutErrorAsk Lorin
SE8Parts processing timeoutErrorAsk Lorin
SE9Parts curing timeoutErrorAsk Lorin

SF50 and SF100 error codes 7 codes

CodeWhat the screen saysTypeHelp
FWH0028No description on fileErrorAsk Lorin
FWI0007No description on fileErrorAsk Lorin
FWS0138Process Chamber Bottom Wall Heating Timeout / Process chamber bottom heating timeoutErrorAsk Lorin
FWS0139Process Chamber Left Wall Heating Timeout / Process chamber left heating timeoutErrorAsk Lorin
FWS0140Process Chamber Right Wall Heating Timeout / Process chamber right heating timeoutErrorAsk Lorin
FWS0141Solvent Boiler 1 Heating Timeout / Solvent boiler heating timeoutErrorAsk Lorin
FWS0142Impeller heating timeout / Solvent Boiler 2 Heating TimeoutErrorAsk Lorin

No code on the screen, or an SFX? Describe the fault to Lorin, or request a visit. Switch off and isolate the machine before opening any panel.